国内精品久久久91性色-亚洲一区二区精品动漫-国产粉嫩精品一二三区-亚洲精品国产欧美在线

 歡迎訪問濟南科爾超聲波設(shè)備有限公司網(wǎng)站!

專注生產(chǎn)工業(yè)用超聲波清洗機

讓工業(yè)清洗無難事

電話

業(yè)務(wù)咨詢電話:

18663767799

你所在位置: 首頁-新聞動態(tài)-新聞資訊面對全自動超聲波清洗機這三種故障怎么處理?
新聞資訊

面對全自動超聲波清洗機這三種故障怎么處理?

作者:admin來源:http://hn-qzj.com/時間:2023-02-28

全自動超聲波清洗機將功率超聲頻源的聲能轉(zhuǎn)換成機械振動,破壞污物與清洗件表面的吸附,引起污物層的疲勞破壞而被駁離,氣體型氣泡的振動對固體表面進行擦洗。那么面對全自動超聲波清洗機這三種故障怎么處理?
The full-automatic ultrasonic cleaning machine converts the sound energy of the power ultrasonic frequency source into mechanical vibration, destroys the adsorption between the dirt and the surface of the cleaning part, causes the fatigue damage of the dirt layer and is removed, and the vibration of gas-type bubbles scrubs the solid surface. So how to deal with these three kinds of faults of automatic ultrasonic cleaning machine?
散熱風(fēng)扇能轉(zhuǎn)動,但無超聲波輸出
The cooling fan can rotate, but there is no ultrasonic output
可能是因為功率管損壞或保險絲熔斷,主板上的功率管會因為機器的長時間使用,導(dǎo)致功率管出現(xiàn)短路情況。
It may be because the power tube is damaged or the fuse is blown. The power tube on the main board will be short-circuited due to the long time use of the machine.
功率管在主板上連接時,用萬用表測量功率管兩側(cè)管腳的阻值。
When the power tube is connected on the main board, use a multimeter to measure the resistance of the pins on both sides of the power tube.
開啟電源就跳閘
Trip when the power is turned on
需要檢查發(fā)生器電源線有無短路,發(fā)生器整流橋是否有問題,可使用萬用表測量發(fā)生器整流橋四個腳有沒短路,如果短路了,需要更換整流橋。
It is necessary to check whether the generator power line has a short circuit and whether the generator rectifier bridge has a problem. Use a multimeter to measure whether the four pins of the generator rectifier bridge have a short circuit. If there is a short circuit, replace the rectifier bridge.
全自動超聲波清洗機
清洗效果不理想
The cleaning effect is not ideal
造成這個問題有可能是因為超聲波頻率協(xié)調(diào)沒有調(diào)節(jié)好、清洗槽內(nèi)的清洗液液位放置不當(dāng)或液體溫度過高、使用的清洗液不符合規(guī)格,這些需要根據(jù)設(shè)備及被清洗物品的材質(zhì)大小所調(diào)節(jié)。
This problem may be caused by improper adjustment of the ultrasonic frequency coordination, improper placement of the cleaning fluid level in the cleaning tank or high liquid temperature, and the use of cleaning fluid that does not meet the specifications. These need to be adjusted according to the material size of the equipment and the cleaned items.
為了不影響設(shè)備的正常使用,一旦發(fā)現(xiàn)問題需及時進行維修處理,不可帶“病”工作,以免造成更大的損傷。您有需求就來我們網(wǎng)站http://hn-qzj.com進行咨詢了解吧!
In order not to affect the normal use of the equipment, once problems are found, they need to be repaired and handled in time. Do not work with "disease" to avoid causing greater damage. Come to our website if you need http://hn-qzj.com Consult and understand!